Standing seam cold roof on open gap timber boarding.
Vmz standing seam roof.
Standing seam cold roof on vented plywood.
Standing seam warm roof on insulated metal faced panels.
Discreet seaming is made on the roof using zinc accessories ensuring watertightness.
Vmz standing seam in quartz zinc 3 vmz stamped weather cock 4 vmz dolphin bend.
Stages to install single lock standing seam.
Functional reliable 1 warszawa poland architect.
Vmz standing seam in quartz zinc 2 pouliacq france architect.
Fixed through to the deck with special fixing clips and screws supplied by vmzinc.
Zinc plus single lock standing seam slss is installed on a minimum 15 mm plywood.
The vmzinc is installed on metal or wooden support.
Vmzinc double lock standing seam system can have application on curved complex and 2 3 dimensional roofs in various types of buildings such as auditoriums railway stations museums commercial buildings private residences airports etc.
A continuous 38 mm ventilated air gap is to be left behind the boarding on the entire facade.
A standing seam metal roof system from western metal deck is one of the most durable and weathertight roof systems available in the industry.
Continuous ventilation openings are made at the top and bottom.
Surface finishes as follows.
Atelier du té technique.
Vmzinc recommends using the double welt over the single welt for standing seam techniques as it provides greater water resistance.
Clips have a dual function.
Air inlets and outlets shall be provided at both top and bottom.
An anti abrasive building paper i e tyvek must be laid between zinc plus and plywood.
Clipless one piece positive locking standing seam panel that provides a timeless roof appearance.
In order to keep the integrity of the roof it is recommended to install vmzinc breather membrane on the cold side of the insulation and a vapour control layer adapted to the internal humidity load of the building on the warm side of the insulation.
With this warm roof system zinc plus standing seam can be installed on rigid insulation without ventilating the underside of the zinc plus.
Standing seam warm roof on rigid insulation.
A 20 mm continuous ventilation gap must be left clear beneath the plywood.
Standing seam warm roof on plywood bonded to phenolic foam.
Continuous ventilation openings must be made at the top and bottom.
Standing seam g3.
Standing seam warm roof on cellular glass insulation.
So when your design requires a metal roofing system that is both aesthetically pleasing and structurally sound choose a western lock standing seam metal roof system.
The clips from vmzinc are made of 304 stainless steel.
Fo damian kotwichi technique.
Allowing free expansion of the metal.